Regimen maintenance of the glove box

From Fake News
Revision as of 12:23, 17 April 2021 by Fruitnews8 (talk | contribs) (Created page with "Etelux reminds you that in addition to the normal inspection of the glove box, the daily servicing perform of the glovebox is also necessary<br /><br />1. Before and right aft...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Etelux reminds you that in addition to the normal inspection of the glove box, the daily servicing perform of the glovebox is also necessary

1. Before and right after each and every perform, first cleanse the atmosphere to make the ground dry and clean. Then clean the equipment, including the internal and outer surfaces of the glove box, the observation method, the function floor, and so on., to be free of charge of particles and clean.

two. Meticulously record the water, oxygen material, and fuel use of the tools in the glove box each and every day to avoid insufficient gasoline strain and result in the gear to stop running.

3. Shell out consideration to the quantity of gasoline in the functioning fuel cylinder at any time and substitute it in time.



4. In situation of electricity failure, push the “vacuum pump” button on the panel to make the vacuum pump operate following electricity on.

5. Be aware: Right after power on, if there is a problem that it can not begin, the likelihood is that the vacuum pump electricity cable is loosely linked. The next reason is that the vacuum pump’s very own switch is not turned on.

six. When you want to place the sample into the glove box, use a little transition chamber as a lot as feasible. Before opening the transition doorway, spend attention to regardless of whether the stress gauge pointer on the valve cavity is at the zero place. If it is, you can open up it directly if not, you want to change the switch under the valve cavity to the “filling” situation to permit the gasoline enter the glove box transition compartment, and then turn the change again to the intermediate placement, then you can open the transition compartment Put the sample in the door, and then shut the door. When placing 4-port glovebox, , be mindful not to touch the internal wall of the changeover chamber with your hands, use gloves to decide and place the samples.

Undertaking these program routine maintenance duties can reduce the decline price of the glove box, extend the provider daily life of the glove box, and also minimize the incidence of incidents